Specifications and models | LC200-2000-400 |
Output voltage | 2000V |
Output current | ±400A |
Output power | ±200kW |
Energy feedback | Support energy recuperation and feed back to the grid |
Isolation function | Inputs and outputs are galvanically isolated |
AC characteristics | |
Rated voltage | 400Vac |
Voltage range | 360Vac~440Vac |
Rated frequency | 50Hz/60Hz |
Frequency range | 47Hz~63Hz |
DC voltage\current | |
Voltage regulation range | 0~2000Vdc |
Voltage setting accuracy | ≤0.05%FS |
Voltage setting resolution | 0.01V |
Voltage display accuracy | ≤0.05%FS |
Voltage display resolution | 0.01V |
Voltage ripple | ≤0.2%FS |
Current regulation range | -400A~400A |
Current setting accuracy | ≤0.05%FS |
Current setting resolution | 0.01A |
Current display accuracy | ≤0.05%FS |
Current display resolution | 0.001A |
Current rise time | ≤3ms(10%~90%) |
Current switching time | ≤6ms(-90%~90%) |
Battery simulation function | |
Battery type | It can simulate different battery types such as lithium iron phosphate, ternary lithium, and lead-acid batteries |
Set the parameters | Parameters such as battery type, series, number of parallels, SOC, cell capacity, etc |
Display parameters | Real-time SOC curve, current capacity, current power, cumulative charge/discharge energy, cumulative charge/discharge energy, running time and other parameters |
IV curve simulation function | |
Open circuit voltage range | 10~2000V |
Short-circuit current setting | 0A~400A |
Type of photovoltaic panel | CSi,TF,SCMC,HEC,Customize |
Fill factor | 0.25~0.95 |
IV curve function | PV scanning, tracking efficiency test, PV curve (including multi-peak) generation, dynamic and static MPPT test, shadow occlusion, cloud drift |
Support standards | EN50530,Sandia,NBT/32004,CGC/GF035,CGC/GF004 |
Programming features | |
The number of programming steps | 300 steps |
Programmatically | Through the number of steps, the number of cycles, the execution mode, the step jump, etc., it can be combined into a multi-sequence complex output mode to meet the test of complex working conditions, and can be applied to the programming test of voltage, current, power and other parameters |
Trigger mode | Manual trigger, delayed trigger |
Other parameters | |
Working mode | Constant voltage, constant current, constant power, constant resistance, support programming, battery simulation, IV curve can be set |
efficiency | ~93% |
Factor | 0.99 |
harmonic wave thd | ≤3% |
Protection features | Over-voltage, over-current, under-voltage, over-temperature, fan failure, etc |
Communication interface | RS485,CAN,LAN,E-stop interface , etc |
Control mode | Touch screen, host computer |
Heat dissipation | Forced air cooling |
Operating temperature | -10ºC~50ºC(Derating above 40°C) |
Storage temperature | -20ºC~70ºC |
relative humidity | 0-90%(Non-condensing) |
Structural dimensions | 1005mm*2100mm*1200mm |
(W*H*D) | |
weight | 2000KG |
elevation | ≤2000m |