Customization: | Available |
---|---|
After-sales Service: | 1 Year Warranty |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | Channel Number |
Voltage | Current | Power | Accuracy | Resolution | Communication Interface |
Size |
N36225-20-275 | 1 | 20V | 275A | 2,500W | ≤0.03%+0.02%F.S. | 1mV | LAN/RS232/RS485/CAN | 44.5mm(H)*214mm(W)*555mm(D) |
N36205-40-50 | 1 | 40V | 50A | 500W | ≤0.03%+0.02%F.S. | 1mV | LAN/RS232/RS485/CAN | 44.5mm(H)*214mm(W)*390mm(D) |
N36212-80-42 | 1 | 80V | 42A | 1,200W | ≤0.03%+0.02%F.S. | 1mV | LAN/RS232/RS485/CAN | 44.5mm(H)*214mm(W)*555mm(D) |
1. R&D laboratory
2. Aerospace&automotive electronics
3. ATE test system
4. Storage battery
5. Consumer electronics
Ultra compact size, high power density
N36200 series supports CC&CV priority function, users can choose the optimal working mode for testing according to the characteristics of DUT.
As shown in figure one, when the DUT needs to avoid the voltage overshoot during testing, the voltage priority mode should be used to obtain a fast and smooth rise voltage.
As shown in figure two, when the DUT needs to avoid the current overshoot, or the DUT is low impedance, the current priority mode should be used to obtain a fast and smooth rising current.
Model | N36216-80-42 | ||
Voltage | 0~80V | ||
Current | 0~42A | ||
Power | 1600W | ||
CV Mode | |||
Range | 0~80V | ||
Setting Resolution | 1mV | ||
Setting Accuracy (23±5ºC) | ≤0.03%+0.02%F.S. | ||
Voltage Ripple(20Hz-20MHz) | ≤80mVp-p | ||
CC Mode | |||
Range | 0~42A | ||
Setting Resolution | 1mA | ||
Setting Accuracy (23±5ºC) | ≤0.1%+0.1%F.S. | ||
Current Ripple(20Hz-20MHz) | ≤50mArms | ||
CP Mode | |||
Range | 1600W | ||
Setting Accuracy (23±5ºC) | 0.1W | ||
Setting Accuracy (23±5ºC) | 0.5%F.S. | ||
Voltage Measurement | |||
Range | 0~80V | ||
Readback Resolution | 1mV | ||
Readback Accuracy (23±5ºC) | ≤0.03%+0.02%F.S. | ||
Current Measurement | |||
Range | 0~42A | ||
Readback Resolution | 1mA | ||
Readback Accuracy (23±5ºC) | ≤0.1%+0.1%F.S. | ||
Line Regulation | |||
Voltage | ≤0.01%F.S. | ||
Current | ≤0.02%F.S. | ||
Load Regulation | |||
Voltage | ≤0.01%F.S. | ||
Current | ≤0.05%F.S. | ||
Dynamic Characteristics | |||
Voltage Rise Time(no load) | ≤10ms | Voltage Fall Time(no load) | ≤25ms |
Voltage Rise Time(full load) | ≤10ms | Voltage Fall Time(full load) | ≤10ms |
Transient Recovery Time | The output voltage recovering within 0.5% of the rated output voltage value (10%~90% load)≤2ms | ||
Others | |||
Isolation(Output to Ground) | 500V DC | ||
Interface | LAN/RS232/RS485/CAN | ||
Communication Response Time | 5ms | ||
AC Input | 220VAC±10%,47Hz~63Hz | ||
Temperature | Operating temperature: 0ºC-40ºC , storage temperature: -10ºC~70ºC | ||
Operating Environment | Altitude <2000m, relative humidity: 5%-90%RH(non-condensing), atmospheric pressure: 80-110kPa | ||
Net Weight | Approx. 4.3kg | ||
Dimension | 44.5(H)*214.0(W)*440.0(D)mm, with output shield |