Model | Channel Number |
Voltage | Current | Power | Accuracy | Resolution | Communication Interface |
Size |
N3608-080-060 | 1 | 80V | 60A | 800W | Voltage≤0.03%+20mV/Current≤0.1%+60mA | 10mV/30mA | RS232/USB/GPIB | 2U |
N3612-080-060 | 1 | 80V | 60A | 1,200W | Voltage≤0.03%+20mV/Current≤0.1%+60mA | 10mV/30mA | RS232/USB/GPIB | 2U |
N3612-240-030 | 1 | 240V | 30A | 1,200W | Voltage≤0.03%+60mV/Current≤0.1%+30mA | 30mV/15mA | RS232/USB/GPIB | 2U |
N3618-080-120 | 1 | 80V | 120A | 1,800W | Voltage≤0.03%+20mV/Current≤0.1%+120mA | 10mV/60mA | RS232/USB/GPIB | 2U |
N3618-240-060 | 1 | 240V | 60A | 1,800W | Voltage≤0.03%+60mV/Current≤0.1%+60mA | 30mV/30mA | RS232/USB/GPIB | 2U |
N3618-500-020 | 1 | 500V | 20A | 1,800W | Voltage≤0.03%+125mV/Current≤0.1%+20mA | 62.5mV/10mA | RS232/USB/GPIB | 2U |
N3618-750-015 | 1 | 750V | 15A | 1,800W | Voltage≤0.03%+180mV/Current≤0.1%+16mA | 90mV/8mA | RS232/USB/GPIB | 2U |
N3618-1000-010 | 1 | 1000V | 10A | 1,800W | Voltage≤0.03%+250mV/Current≤0.1%+10mA | 125mV/5mA | RS232/USB/GPIB | 2U |
N3630-080-120 | 1 | 80V | 120A | 3,000W | Voltage≤0.03%+20mV/Current≤0.1%+120mA | 10mV/60mA | RS232/USB/GPIB | 2U |
N3630-240-060 | 1 | 240V | 60A | 3,000W | Voltage≤0.03%+20mV/Current≤0.1%+120mA | 10mV/60mA | RS232/USB/GPIB | 2U |
N3630-500-020 | 1 | 500V | 20A | 3,000W | Voltage≤0.03%+125mV/Current≤0.1%+20mA | 62.5mV/10mA | RS232/USB/GPIB | 2U |
N3630-750-015 | 1 | 750V | 15A | 3,000W | Voltage≤0.03%+180mV/Current≤0.1%+16mA | 90mV/8mA | RS232/USB/GPIB | 2U |
N3630-1000-010 | 1 | 1000V | 10A | 3,000W | Voltage≤0.03%+250mV/Current≤0.1%+10mA | 125mV/5mA | RS232/USB/GPIB | 2U |
1. New energy fields, such as Li-on battery, photovoltaic, hydrogen fuel, energy storage BMS, etc.
2. Civil fields, such as home appliances, consumer electronics, communications, etc.
3. Laboratory, production line ATE automatic test system
4. Automotive fields, such as BMS, DC-DC, automotive electronics, etc.
5. Testing and powering of aerospace electronics
6. Industrial automation fields, such as controllers, drives, servers, robots, etc.
SEQ function
Voltage up to 1200V, making high voltage test more secure
N3600 series supports up to 1200V. In the fields of LED, battery, DC/DC converter and other industries, high voltage is the basic need for power supplies. Besides the above mentioned industries, N3600 series can also be applied for special tests with extremely high voltage requirements.
The safety of high-voltage test has always been a concern of engineers. NGI puts emphasis on details like the safety terminals design to ensure the safety of the test.
Wide range for saving purchase cost
N3600 series' Max. power is not the result of Max. voltage multiplied by the Max. current. Take model N3630-240-060 for example. The Max. power is 3kW while the Max. voltage 240V and Max. current 60A. The single model can replace two devices or more common power supplies.
External dissipater function
When using N3600 to supply power to inductive loads such as motors, users press ON/OFF button on N3600's front panel to stop power supply. At this time, the motor may return a voltage greater than the setting value of N3600, which is likely to damage N3600 and the motor. Users can connect a load to N3600 as a dissipater. The setting voltage of the load must be an increment higher than the setting voltage of N3600. When the setting voltage of the load is higher than the setting voltage of N3600, the load will not work. If the voltage returned by the motor is exceeding the setting voltage of the load, the load starts to work to protect N3600 and the motor controller.
Model | N3608-080-060 | N3612-080-060 | N3612-240-030 | N3618-016-250 | N3618-080-120 |
Voltage | 0-80V | 0-80V | 0-240V | 0-16V | 0-80V |
Current | 0-60A | 0-60A | 0-30A | 0-250A | 0-120A |
Power | 800W | 1200W | 1200W | 1800W | 1800W |
CV Mode | |||||
Range | 0-80V | 0-80V | 0-240V | 0-16V | 0-80V |
Setting Resolution | 1mV | 1mV | 10mV | 1mV | 1mV |
Setting Accuracy (23±5ºC) | 0.05%+0.05%F.S. | ||||
CC Mode | |||||
Range | 0-60A | 0-60A | 0-30A | 0-250A | 0-120A |
Setting Resolution | 1mA | 1mA | 1mA | 10mA | 10mA |
Setting Accuracy (23±5ºC) | 0.1%+0.1%F.S. | ||||
Voltage Measurement | |||||
Range | 0-80V | 0-80V | 0-240V | 0-16V | 0-80V |
Readback Resolution | 1mV | 1mV | 10mV | 1mV | 1mV |
Readback Accuracy (23±5ºC) | 0.05%+0.05%F.S. | ||||
Temperature Coefficient | 50ppm/ºC | ||||
Current Measurement | |||||
Range | 0-60A | 0-60A | 0-30A | 0-250A | 0-120A |
Readback Resolution | 1mA | 1mA | 1mA | 10mA | 10mA |
Readback Accuracy (23±5ºC) | 0.1%+0.1%F.S. | ||||
Temperature Coefficient | 50ppm/ºC | ||||
Line Regulation | |||||
Voltage | ≤0.01% | ||||
Current | ≤0.05% | ||||
Load Regulation | |||||
Voltage | ≤0.05% | ||||
Current | ≤0.05% | ||||
Dynamic Characteristics | |||||
Voltage Rise Time (no load) | ≤20ms | ≤20ms | ≤60ms | ≤10ms | ≤20ms |
Voltage Rise Time (full load) | ≤500ms | ≤300ms | ≤500ms | ||
Voltage Fall Time (no load) | ≤700ms | ≤700ms | ≤300ms | ≤50ms | ≤700ms |
Voltage Fall Time (full load) | ≤20ms | ≤20ms | ≤50ms | ≤5ms | ≤20ms |
Transient Recovery Time | The recovery time of load varying from 10% to 90% and output voltage recovering within 0.5% of rated voltage is less than 20ms. | ≤80ms | ≤20ms | ||
Output Ripple(20Hz-20MHz) | |||||
Voltage Ripple (P-P) | ≤300mVp-p | ≤300mVp-p | ≤400mVp-p | ≤400mVp-p | ≤400mVp-p |
Others | |||||
Efficiency | 90%(Typical) | ||||
Interface | RS232/LAN | ||||
Communication Response Time | ≤5ms | ||||
AC Input | Single phase, please refer to the voltage mark at the rear panel. | ||||
Temperature | Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC | ||||
Operating Environment | Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa | ||||
Net Weight | Approx. 15.5kg | 16.5kg | 18kg | ||
Dimension | 2U, 88.0(H)*482.0(W)*550.0(D)mm |