Customization: | Available |
---|---|
After-sales Service: | 1 Year Warranty |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | Channel Number |
Voltage | Current | Power | Accuracy | Resolution | Communication Interface |
Size |
N39220-60-10 | 2 | 60V | 10A | 200W | Voltage≤0.05%+0.1%F.S. / Current≤0.1%+0.1%F.S. | 1mV / 1mA | LAN/RS232 | 2U |
N39240-60-20 | 2 | 60V | 20A | 400W | Voltage≤0.05%+0.1%F.S. / Current≤0.1%+0.1%F.S. | 1mV / 1mA | LAN/RS232 | 2U |
N39260-60-20 | 2 | 60V | 20A | 600W | Voltage≤0.05%+0.1%F.S. / Current≤0.1%+0.1%F.S. | 1mV / 1mA | LAN/RS232 | 2U |
N39220-150-04 | 2 | 150V | 4A | 200W | Voltage≤0.05%+0.1%F.S. / Current≤0.1%+0.1%F.S. | 10mV / 1mA | LAN/RS232 | 2U |
N39240-150-08 | 2 | 150V | 8A | 400W | Voltage≤0.05%+0.1%F.S. / Current≤0.1%+0.1%F.S. | 10mV/1mA | LAN/RS232 | 2U |
N39260-150-08 | 2 | 150V | 8A | 600W | Voltage≤0.05%+0.1%F.S. / Current≤0.1%+0.1%F.S. | 10mV/1mA | LAN/RS232 | 2U |
1. Laboratory test
2. System integration test
3. Production line aging
N39200 series adopts 2U and half 19 inch design, with 2 channels in a single device. Each channel is isolated. One device can support 2-station test simultaneously, which simplifies the test platform and improves test efficiency.
UI flat icons
UI flat icons offer convenient and quick operation.
Virtual keypad
SEQ mode
SEQ mode allows setting of output voltage, output current and dwell time for single step.
Cascade mode for power expansion
N39200 supports two channels parallel mode internally. Under parallel mode, the output voltage remains the same. The output current and power will be doubled.
N39200 has the function of selecting priority of voltage-control loop or current-control loop, which enables N39200 to adopt the optimal test mode for different DUTs, and thus protect the DUT.
As shown in figure one, when the DUT requires reducing voltage overshoot during test, such as supplying power to a low-voltage processor or FPGA core, voltage priority mode should be selected to obtain fast and smooth rise voltage.
Dual LAN ports for multiple devices control
N39200 is equipped with two LAN ports, which can support multiple devices control for quick adjustment and test.
Model | N39220-60-10 | N39240-60-20 | N39260-60-20 | N39220-150-04 | N39240-150-08 | N39260-150-08 |
Voltage | 60V/CH | 150V/CH | ||||
Current | 10A/CH | 20A/CH | 20A/CH | 4A/CH | 8A/CH | 8A/CH |
Power | 200W/CH | 400W/CH | 600W/CH | 200W/CH | 400W/CH | 600W/CH |
Channels | 2CH | |||||
CV Mode | ||||||
Range | 0-60V | 0-150V | ||||
Setting Resolution | 1mV | 10mV | ||||
Setting Accuracy ( 23±5ºC ) | 0.05%+0.1%F.S. | |||||
Setting Temperature Coefficient ( 0-40ºC ) | 50ppm /ºC | |||||
Readback Resolution | 1mV | 10mV | ||||
Readback Accuracy ( 23±5ºC ) | 0.05%+0.1%F.S. | |||||
Readback Temperature Coefficient ( 0-40ºC ) | 50ppm /ºC | |||||
CC Mode | ||||||
Range | 0-10A | 0-20A | 0-20A | 0-4A | 0-8A | 0-8A |
Setting Resolution | 1mA | 0.1mA | ||||
Setting Accuracy( 23±5ºC ) | 0.1%+0.1%F.S. | |||||
Setting Temperature Coefficient ( 0-40ºC ) | 50ppm /ºC | |||||
Readback Resolution | 1mA | 0.1mA | ||||
Readback Accuracy ( 23±5ºC ) | 0.1%+0.1%F.S. | |||||
Readback Temperature Coefficient ( 0-40ºC ) | 50ppm/ºC | |||||
Output Noise & Ripple(20Hz-20MHz) | ||||||
Voltage Ripple | 150mVp-p | 200mVp-p | ||||
10mVrms | 15mVrms | |||||
Line Regulation | ≤0.015%(Voltage) | |||||
Load Regulation | ≤0.01%(Voltage) | |||||
Voltage Rise Time (no load) | ≤30ms | |||||
Voltage Fall Time (no load) | ≤30ms | |||||
Others | ||||||
Interface | LAN/RS232 | |||||
AC Input | Single phase, 220V AC±10%, frequency 47Hz~63Hz | |||||
Temperature | Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC | |||||
Operating Environment | Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa | |||||
Dimension | 2U, 88.0(H)*214.0(W)*546.0(D)mm | |||||
Net Weight | Approx. 7 kg |