Customization: | Available |
---|---|
After-sales Service: | 1 Year Warranty |
Warranty: | 1 Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Basic parameters | ||
Input parameters | Connection | Three-phase three-wire+PE |
Input frequency(Hz) | 47~63 | |
Voltage range | 304~480Vac | |
Output mode | AC, DC, AC DC, DC AC | |
Operating mode | Bidirectional feedback source | |
AC output | ||
voltage |
Resolution settings(V) | 0.01 |
precision | ±0.1%FS | |
DC component(mV) | <50 | |
Voltage distortion | Linear loads<1% | |
Load Adjustment Rate | ±0.1%FS | |
Source Adjustment Rate | ±0.1%FS@10% variation | |
Voltage slew rate | AC>1.0V/us | |
Three-phase imbalance | Not more than 1/2 of the requirements of GB/T 15543-2008 (negative sequence voltage does not exceed 1%, short time does not exceed 2%) | |
Current | accuracy | 0.1%+0.1%F.S.@15~200Hz |
frequency | resolution(Hz) | 0.001 |
precision | ±0.01% | |
phase | range | A=0°, B=240°, C=120° (default); Programmable range: 0°~359.9° |
precision | ±0.1°@15~70Hz;±0.5°@70~200Hz | |
Resolution settings | 0.1° | |
Internal resistance mode |
R range ( 2 ) | 0~10@Impedance at steady-state output |
Lrange(mH) | 0~2 | |
Resolution settings | 0.001 | |
precision | 0.1%+0.2%FS | |
harmonic wave |
frequency | 50 times @40~70Hz, 25 times @70~200Hz |
content | Up to 40% for a single time, up to 40% of total content | |
Amplitude error | ±5%@0.1% of the set value or fundamental value@39 | |
Phase angle range | 0°~359.9° | |
Preview features | Harmonic overlay waveforms can be previewed | |
Edit mode | Import, export, read, store | |
DC output | ||
voltage |
Resolution settings(V) | 0.01 |
Output accuracy | ±0.1%FS | |
Output ripple (V_rms) | <1.5@(DC~60kHz) | |
Load Adjustment Rate | ±0.05%FS | |
Source Adjustment Rate | ±0.01%FS@10%variation | |
Output slew rate | DC>1.0V/us | |
Current | Resolution settings(A) | 0.01 |
precision | ±(0.1%+0.1%FS) | |
Programming features | ||
mode | LIST,WAVE,Advanced,Harmonics, interharmonics, 30 groups of DST | |
Minimum programming time step | 1ms | |
Number of programmed waveforms | 100 | |
Synchronization source/trigger source | Internal, external | |
Data sources | Edit, import, export | |
RLC load | ||
resistance | range(Ω) | 0.001~1000 |
Resolution settings(Ω) | 0.001 | |
precision | ±0.1%FS | |
inductance | range ( m H ) | 1~5000 |
Resolution settings(mH) | 0.001 | |
precision | ±0.1%FS | |
capacitance | range ( m F ) | 1~5000 |
Resolution settings(mF) | 0.001 | |
precision | ±0.1%FS | |
Peak factor | range | 1.000~5.000 |
resolution | 0.001 | |
Power factor | range | -1.000~1.000 |
resolution | 0.001 | |
Measurement parameters | ||
Voltage accuracy | ±0.1%FS | |
Current accuracy | ±(0.1%+0.2%FS) | |
Frequency accuracy | ±0.01% | |
Active power accuracy | ±0.5%FS | |
Apparent power accuracy | ±0.5%FS | |
Other parameters | ||
efficiency | >91% | |
Power factor | ≥0.96 | |
Protective functions | Overvoltage/undervoltage, over/under frequency, overcurrent, overtemperature, fan failure, etc | |
Communication interface | Type-B USB,LAN,RS485 | |
Control mode | Touch screen, host computer | |
Cooling method | Forced air cooling | |
noises | ≤70dB | |
Operating temperature range(ºC) | -10~50 | |
relative humidity | 10%~90%RAH | |
altitude | ≤2000m |