Customization: | Available |
---|---|
After-sales Service: | 1 Year Warranty |
Warranty: | 1 Year |
Still deciding? Get samples of $ !
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
N39400 series Programmable DC Power Supply with High-accuracy Multi-channel
Model | Channel Number |
Voltage | Current | Power | Accuracy | Resolution | Communication Interface |
Size |
N39420-60-10 | 4 | 60V | 10A | 200W | Voltage≤0.05%+0.1%F.S./Current≤0.1%+0.1%F.S. | 1mV/1mA | LAN/RS232 | 2U |
N39436-60-15 | 4 | 60V | 15A | 360W | Voltage≤0.05%+0.1%F.S./Current≤0.1%+0.1%F.S. | 1mV/1mA | LAN/RS232 | 2U |
N39420-150-04 | 4 | 150V | 4A | 200W | Voltage≤0.05%+0.1%F.S./Current≤0.1%+0.1%F.S. | 10mV/1mA | LAN/RS232 | 2U |
N39436-150-06 | 4 | 150V | 6A | 360W | Voltage≤0.05%+0.1%F.S./Current≤0.1%+0.1%F.S. | 10mV/1mA | LAN/RS232 | 2U |
N39460-60-15 | 4 | 60V | 15A | 600W | Voltage≤0.05%+0.1%F.S./Current≤0.1%+0.1%F.S. | 1mV/1mA | LAN/RS232 | 2U |
N39460-150-06 | 4 | 150V | 6A | 600W | Voltage≤0.05%+0.1%F.S./Current≤0.1%+0.1%F.S. | 10mV/1mA | LAN/RS232 | 2U |
1. Laboratory test
2. System integration test
3. Production line aging
N39400 series adopts the standard 19-inch 2U design, with Max.4 channels in a single device. Each channel is isolated.One device can support 4-station test simultaneously, which greatly reduces the test equipment quantity and improves test efficiency.
N39400 series supports remote control, providing RS232 and LAN port to communicate with the computer, and realizing all functions on the panel via computer application software.
NN39400 series provides remote sense function, which can transfer the actual voltage of the load back to N39400 so that N39400 can compensate for the output voltage and eliminate lead wire errors.
UI flat icons
UI flat icons offer convenient and quick operation.
N39400 has the function of selecting priority of voltage-control loop or current-control loop, which enables N39400 to adopt the optimal test mode for different DUTs, and thus protect the DUT.
As shown in figure one, when the DUT requires reducing voltage overshoot during test, such as supplying power to a low-voltage processor or FPGA core, voltage priority mode should be selected to obtain fast and smooth rise voltage.
Model | N39420-60-10 | N39436-60-15 | N39460-60-15 |
Voltage | 60V/CH | ||
Current | 10A/CH | 15A/CH | 15A/CH |
Power | 200W/CH | 360W/CH | 600W/CH |
Channels | 4CH | ||
CV Mode | |||
Range | 0-60V | ||
Setting Resolution | 1mV | ||
Setting Accuracy (23±5ºC) | 0.05%+0.1%F.S. | ||
Setting Temperature Coefficient | 50ppm/ºC | ||
Readback Resolution | 1mV | ||
Readback Accuracy(23±5ºC) | 0.05%+0.1%F.S. | ||
Readback Temperature Coefficient | 50ppm/ºC | ||
CC Mode | |||
Range | 0-10A | 0-15A | 0-15A |
Setting Resolution | 1mA | ||
Setting Accuracy (23±5ºC) | 0.1%+0.1%F.S. | ||
Setting Temperature Coefficient | 50ppm/ºC | ||
Readback Resolution | 1mA | ||
Readback Accuracy (23±5ºC) | 0.1%+0.1%F.S. | ||
Readback Temperature Coefficient | 50ppm/ºC | ||
Voltage Ripple(20Hz-20MHz) | 200mVp-p | ||
10mVrms | |||
Rise Time | ≤30ms | ||
Fall Time | ≤50ms | ||
Load Regulation | ≤0.01%(Voltage) / ≤0.03%(Current) | ||
Line Regulation | ≤0.01%(Voltage) / ≤0.02%(Current) | ||
Others | |||
Interface | LAN/RS232 | ||
AC Input | Single phase, 220V AC±10%, frequency 47Hz~63Hz | ||
Temperature | Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC | ||
Operating Environment | Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa |
||
Net Weight | Approx. 10kg | ||
Dimension | 2U, 88.0(H)*482.0(W)*560.0(H)mm |
Model | N39420-150-04 | N39436-150-06 | N39460-150-06 |
Voltage | 150V/CH | ||
Current | 4A/CH | 6A/CH | 6A/CH |
Power | 200W/CH | 360W/CH | 600W/CH |
Channels | 4CH | ||
CV Mode | |||
Range | 0-150V | ||
Setting Resolution | 5mV | ||
Setting Accuracy (23±5ºC) | 0.05%+0.1%F.S. | ||
Setting Temperature Coefficient | 50ppm/ºC | ||
Readback Resolution | 5mV | ||
Readback Accuracy(23±5ºC) | 0.05%+0.1%F.S. | ||
Readback Temperature Coefficient | 50ppm/ºC | ||
CC Mode | |||
Range | 0-4A | 0-6A | 0-6A |
Setting Resolution | 0.1mA | ||
Setting Accuracy (23±5ºC) | 0.1%+0.1%F.S. | ||
Setting Temperature Coefficient | 50ppm/ºC | ||
Readback Resolution | 0.1mA | ||
Readback Accuracy (23±5ºC) | 0.1%+0.1%F.S. | ||
Readback Temperature Coefficient | 50ppm/ºC | ||
Voltage Ripple(20Hz-20MHz) | 200mVp-p | ||
10mVrms | |||
Rise Time | ≤30ms | ||
Fall Time | ≤50ms | ||
Load Regulation | ≤0.01%(Voltage) / ≤0.03%(Current) | ||
Line Regulation | ≤0.01%(Voltage) / ≤0.02%(Current) | ||
Others | |||
Interface | LAN/RS232 | ||
AC Input | Single phase, 220V AC±10%, frequency 47Hz~63Hz | ||
Temperature | Operating temperature: 0ºC~40ºC, storage temperature: -20ºC~60ºC | ||
Operating Environment | Altitude <2000m, relative humidity: 5%~90%RH(non-condensing), atmospheric pressure: 80~110kPa |
||
Net Weight | Approx. 10kg | ||
Dimension | 2U, 88.0(H)*482.0(W)*560.0(H)mm |